R4RIN
MCQS
Civil Engineering MCQ Quiz Hub
Railway Engineering MCQ
Choose a topic to test your knowledge and improve your Civil Engineering skills
1. Which one of the following is the interlocking system used in railway signalling?
Mechanical system
Key system
Electrical system
Electronic system
2. The rail section, nowadays, used in India is
Flat footed
Bull headed
Double headed
I-section
3. Indian Railways has been divided into
10 zone
12 zone
18 zones
19 zone
4. The most widely used gauge in the world is
Broad gauge
Metre gauge
Narrow gauge
Standard gauge
5. The ends of rail getting bent down due to wheel load is known as
Hogged rails
Buckling
Coning
Tilting
6. The sleeper which has excellent ability to absorb shock is
Concrete sleeper
Cast iron sleeper
Steel sleeper
Wooden sleeper
7. Heaviest sleeper is
Cast iron sleeper
Concrete sleeper
Steel sleeper
Wooden sleeper
8. Which one of the following is not used to fix rails to wooden sleepers?
Screw spikes
Dog spikes
Fish bolt
Round spike
9. The stations which do not have any signal are known as
A class stations
B class stations
Terminal stations
Crossing stations
10. The yard for reception, sorting and reforming of goods trains is known as
Marshalling yard
Goods yard
Locomotive yard
All of the above
11. The first train in India was run between
Mumbai to Ahmedabad
Mumbai to Thana
Chennai to Vijaywada
Delhi to Kolkata
12. Rail joint supported on a single sleeper, is known as
bridge rail joint
supported rail joint
square rail joint
suspended rail joint
13. Which one of the following is not a type of crossing used in railways?
square crossing
spring crossing
ramped crossing
rectangular crossing
14. The height of platform above the rails in narrow gauge station should be
0.23 m to 0.41 m
0.31 m to 0.41 m
0.51 m to 0.60 m
0.76 m to 0.84 m
15. Cotters are used to fix
fish plates
tie bars to cast iron sleepers
bearing plate to sleeper
rail to sleeper
16. The first train in India was run in the year
1825
1833
1853
1857
17. 60 R rails are used in
narrow gauge
metre gauge
broad gauge
in all the above
18. The composite sleeper index is the index of
strength and hardness
strength and toughness
hardness and wear resistance
toughness and wear resistance
19. In India, metre guage permanent way was adopted in
1855
1866
1871
1874
20. A mono-block sleeper has
trapezoidal section
semi-circular section
square section
rectangular section
21. The device used to move wagons side way from one track to another track is
traverse
buffer stop
turntable
triangle
22. Rail section first designed on Indian railways was
bull headed
flat footed
double headed
a and b simultaneously
23. The rail is designated by its
cross section
weight per unit length
length
weight
24. The main function of a fish plate is
to allow rail to expand and contract freely
to join rails with the sleeper
to join the two rails together
none of the above
25. At Sonepur in North-East Railways, length of platform is
520 m
666 m
736 m
936 m
26. In urban and suburban stations with heavy traffic, the type of signals preferred are
colour light signals
circular hands with bands
warner signals
semaphore type
27. At a rail joint, the ends of adjoining rails, are connected with a pair of fish plates and
2 fish bolts
4 fish bolts
8 fish bolts
12 fish bolts
28. Steel sleepers are
6mm thick steel sheets with ends bent up
6 mm thick sheets with ends bent down
hollow circular pipes
rectangular cross section throughout
29. Arrangement made to divert the trains from one track to another is known as
railway junction
railway crossing
railway point
turnout
30. Charles Vignoles invented the flat footed rails in
1814
1824
1836
1846
31. The system in which position of trains and signals are displayed and controlled is known as
automatic block system
automatic train control system
absolute block system
centralized traffic control system
32. The yard used for cleaning, repairing, servicing, watering, etc., is known as
locomotive yard
goods yard
marshalling yard
none of the above
33. In Indian Railways highly used sleeper is
wooden sleeper
cast iron sleeper
concrete sleeper
steel sleeper
34. The joint generally used in Indian Railways is
bridge joint
semi supported joint
suspended joint
supported joint
35. The best wood for sleeper is
teak
sal
chir
deodar
36. Indian Railways are provided with _____ of track with steel sleepers.
20%
30%
40%
60%
37. Fish bolts are made from
high carbon steel
wrought iron
mild steel
All of the above
38. The stations which are provided to facilitate overtaking of trains are known as
flag stations
crossing stations
way side stations
All of the above
39. Fish plates should be designed for
vertical force
longitudinal forces
horizontal forces
All of the above
40. The composite sleeper index determines the suitability of
concrete sleepers
cast iron sleepers
wooden sleepers
steel sleepers
41. Maximum degree of curve permitted in Indian Railways in broad gauge is
5°
10°
15°
25°
42. Which one of the following is the duty of daily maintainance gang?
check the fastenings and fixtures
maintain points and crossing
maintain drainage
maintain track alignment
43. The sleepers which satisfy the requirements of an ideal sleeper are
Steel sleepers
Wooden sleepers
R.C.C. Sleepers
Cast iron sleepers
44. Heel of crossing is the line joining
throat and actual nose of crossing
ends of wing rails
ends of lead rails butting the crossing
ends of splice rail and point rail
45. Maximum cant deficiency prescribed on Indian Board Gauge Railways, is
25 mm
40 mm
50 mm
100 mm
46. The minimum value of flange way clearance recommended is
50 mm
60 mm
70 mm
80 mm
47. In Indian Railways ruling gradient on plains is
1 in 100 to 1 in 150
1 in 150 to 1 in 200
1 in 200 to 1 in 300
1 in 300 to 1 in 400
48. Life of steel sleepers is
20 to 30 years
30 to 40 years
40 to 50 years
50 to 60 years
49. On Indian Railways, number of a crossing is defined as
tangent of angle of crossing
contangent of angle of crossing
consine of angle of crossing
sine of angle of crossing
50. Two important constituents in the composition of steel used for rail are
carbon and sulphur
carbon and manganese
carbon and silicon
manganese and phosphorous
51. World's narrowest gauge is
610 mm
762 mm
924 mm
1000 mm
52. Non-corrosive material applied to rails consist of
red oxide + zinc chlorite + bituminous emulsion
red oxide + aluminium coat
red oxide + zinc chromate coat
red oxide coat
53. A CST-9 sleeper is
box sleeper
pot sleeper
plate sleeper
combination of all the above
54. The station consisting of a block hut only and having home and warner signals is classified as
A class station
B class station
C class station
D class station
55. Rail section is generally designated by its
area of its cross section
weight per metre length
total length
total weight
56. The longitudinal movement of the rails in a track is known as
buckling
creeping
hogging
tilting
57. At road and rail level crossing, road should be straight at least for
20 m
30 m
40 m
50 m
58. Gauge of a permanent way is
width of formation
distance between centres of rails
minimum distance between outer faces of rails
minimum distance between running faces of rails
59. minimum distance between running faces of rails
to support rails
to distribution load from the rails to ballast
to hold rails at correct gauge
all the above
60. 52 kg rails are mostly used in
narrow gauge
broad gauge
metre gaue
both a and b
61. The joint that cause greater incidence of rail end batter is
bridge joint
supported joint
semi-supported joint
suspended joint
62. Standard size of wooden sleeper on broad gauge is
1520 x 150 x 100 mm
1830 x 150 x 100 mm
1830 x 200 x 110 mm
2740 x 250 x 130 mm
63. The sleeper in the form of two bowls placed under each rail and connected by a tie bar is known as
box sleeper
plate sleeper
pot sleeper
none of the above
64. In automatic block system when a train is in a block it puts the danger signal till the train moves over
one more block
two more signals
that block
none of the above
65. Staggered rail joints are generally provided
in tunnels
on bridges
on tangents
on curves
66. Type of switch rails generally adopted for modern track is
loose heel switch
straight switch
curved switch
bent switch
67. Gauge is the distance between
outer faces of rails
center to centre of rails
running faces of rails
none of these
68. Pandrol clips cannot be used with
CST-9 sleepers
steel through sleepers
concrete sleepers
wooden sleepers
69. Metal sleepers are superior to wooden sleepers with respect to
life
track circuiting
cost
fastening
Submit